Loading... Please wait...

Our Newsletter


4 Pack of Fluorescent Orange UV Dye Tabs DFTB-33

  • 4 tab pack of DFTB-33 Orange Fluorescent EPA Approved and Certified for Drinking Water Tracer Additive Concentrate.
RRP:
$11.54
Your Price:
$8.95 (You save $2.59)
SKU:
DFTB-33PK4
Weight:
2.00 Ounces
Shipping:
Calculated at checkout
Quantity:


Product Description

DFTB-33 Orange Fluorescent EPA Approved & Certifed for Drinking Water Tracer Additive Concentrate.

* EPA Approved!
* 5/8" Tablets Per Bottle!
* 1 Tablet Will Make 60 Gallons of Tracer!
* Certified to the ANSI/NSF Standard 60 for Potable Water!
* Dissolved in 5-8 Minutes!
* Perfect for Cooling and Plumbing Systems
* Also Sold in Other Sizes!

Available In:
50, 100,200, 2000 tablet containers. Larger units are available upon request.

 General Properties   DFTB-33 Tablets IFWB-33 Liquids   DFWB-33 Powders
 Detectability of active ingredient
 Visual <100 ppb  Visual <100 ppb  Visual <100 ppb
 Maximum absorbance wavelength
 515/535 nm  515/535 nm  515/535 nm
 Appearance  Brick red convex 1.6cm diameter  Reddish-Orange aqueous solution  Brick red fine powder
 max use levels in potable water  0.3 ppb  0.8 ppb  0.1 ppb
 Weight  1.35 gms + 0.05  n/a  n/a
 Dissolution Time 3  50% < 3 minutes
95% < 6 minutes
 n/a

 50% < 3 minutes

95% < 6 minutes

 Specific Gravity  n/a  1.05 Â?} 0.05 @ 25Â?‡ C   n/a
 Viscosity
 n/a  1.8 cps   n/a
 pH  7.5 Â?} 0.5  8.0 Â?} 0.5 @ 25Â?‡ C   n/a
 Coverage of Products  One Tablet  One Pint Liquid  One Pound Powder
 Light Visual (100 ppb)  350 gallons  40,000 gallons  604,000 gallons
 Strong Visual (1 ppm)  35 gallons  4,000 gallons  60,400 gallons

Certified To Meet EPA Standards This is a certification that these products conform to the ANSI/Standard 60 for potable water as set forth by the EPA in The Clean Water Act.

Benefits of Risk Reactor Inc's IFWB-33 UV Orange Water Based Tracer:

  • High strength formulations for medium to large scale visual and fluorometric studies!
  • Most appropriate fluorescent products for quantitative analysis!
  • It is clear when diluted preventing stains and other unwanted marks!
  • Can be detected using one of our (portable battery operated ones available) black lights at significantly lower levels such as in the range of 10 ppb in ideal conditions!
  • Fluoresces under long wave black light!
  • Cleans up with water!
  • Highly concentrated saving you money!
  • Safe and non-toxic!
  • Can be used with our 6" Hand Held Black Light for mobility!
  • BioDegradable!
  • Can be used with UV sensors for automation!
  • Because of the fluorescent nature, IFWB-33 offers greater contrast than non-fluorescent tracers!

Used In:

- Plumbing Tracing.
- Retention Time Studies.
- Flow mapping and rate of flow studies.
- Condenser coil and tube studies.
- Power plant piping tracing.
- Septic system analysis.
- Pollution Studies.
- Leak Detection in many fluid carrying systems.
- Lake river and pond analysis.
- Check for illegal connections.
- Storm and sewer drain analysis.
- Agricultural Agencies.
- Conservation districts.
- Fish and wildlife authorities.
- Fire departments.
- Ocean studies .
- Swimming pool services.
- Geologists.
- Environmental consultants.
- Farms and ranches.
- Food processing. 

How to Use:
How Fluorescent Dye Tracing Products Work: The "visual" aspect of our dye products refers to normal reflection of light as color. The "fluorescent" aspect refers to special properties of some chemicals to absorb certain wavelengths and then emit, rather than reflect, light in response. The emission can be seen by using a "black" ultraviolet light or precisely measure Yellow Green with a fluorometer. The reflected and emitted light have different wavelengths and are, therefore, not the same color.

Fluorescent Properties are of Greatest Value When :
- Tracing must be done when there is no sun or sufficient artificial light (in a sewer or a cave, for instance).
- Precise quantified data is required.
- Very small amounts of tracing material is allowed.  

What Does PPB Mean? Most of our products contain fluorescent dyes, which can be detected visually, or with the use of ultraviolet light or fluorometer. As used in Risk Reactor literature, "ppb" refers to one part of active dye per billion parts of water. Using a fluorometer, the active dye can often be detected at levels less than one ppb. All data is presented as reference points only and should not be regarded as a recommendation. Users should make their own determination of appropriate dilution levels in any specific situation, which will vary with the nature, condition, and use of the water or liquid and the specific evaluation to be performed.

For Stream Tracing and Pollution Detection: Introduce tracers into the water at the source or suspected source of pollution. Allow sufficient time as calculated, to permit the dye tracer to reach the effluent or recipient location. Take samples of water for analysis.

Light Stability: Yellow Green is recommended for yellow and green backgrounds such as algae rich water. Yellow Green, blue, and yellow green should be used in water bearing heavy sediment loads or when passing through soil with high clay content. Industrial Yellow Green will absorb onto either. Photo degradation takes place in sunlight at different rates for different dyes. Yellow Green takes from approximately five to seven days and yellow green fades in two to three days. Blue, on the other hand, breaks down in three to four weeks. The color of all dyes will disappear if the solution is mixed with chlorine. Add approximately 4 grams of 12% bleach to every gram of product in solution.

Examples of Specific Projects: Test sewer lines for infiltration. Locates sewer lines. Check for illegal connections. Prove septic bypasses. Identify indirect cross-connections. Check drain pipes, downspouts, and gutters to assure drainage into proper channels. Use in inspection service for certification and reinspection documentation. Analyze travel times. Toilet leak detection kits are frequently used by plumbers, municipalities and utilities use them as part of public relations and water conservation programs. Detect leaks in closed systems and cooling systems of steel manufacturers. Study infiltration and industrial water piping systems. Trace acid coming though cooling systems. Check pump systems flow in fleet trucks, and for preventative maintenance programs. Detect sewer leaks into ponds, lagoons, and reservoir lines. Check circulation through sludge beds and to measure discharge flow from water tanks. Illustrate the hydraulic characteristics of streams and other water bodies. Identify and differentiate batches of slurry before the brick firing process. Measure the speed and longevity of material passing through a system (i.e. retention time studies).

Caution: These products may cause irritation and/or staining if allowed to come in contact wit the skin. The use of gloves and goggles is recommended when handling this product, as with any other dye or chemical. To our best knowledge the information and recommendations contained herein are accurate and reliable. However, this information and our recommendations are furnished without warranty, representation, inducement, or license of any kind, including, but not limited to the implied warranties and fitness for a particular use or purpose. Customers are encouraged to conduct their own tests and to read the material safety data sheet carefully before using. Risk Reactor also offers a variety of fluorescent (UV), tracers, dyes, pigments, phosphorescent (GID), and black light products.


Product Videos

DFTB C33 ()
  • DFTB C33

Product Videos

Find Similar Products by Category


Write your own product review

Product Reviews

This product hasn't received any reviews yet. Be the first to review this product!


Add to Wish List

Click the button below to add the 4 Pack of Fluorescent Orange UV Dye Tabs DFTB-33 to your wish list.

You Recently Viewed...